Fire Department Shift Schedule

A fire department shift schedule is a three-platoon system of 24-hour tours, such as 24/48, 48/96 or Kelly. Enter your crew's start date to map rotation hours, shift minutes and statutory overtime in your browser. Results are administrative estimates, not legal or payroll counsel.

Free · runs in your browser · nothing is uploaded

Open on Shiftfigure

This embed was switched off for this website. Open on Shiftfigure

Add this tool to your siteFree embed code, no sign-up. Keep the credit link.

Embed this tool

Copy this code into your website, blog or class page. The tool runs inside your page.

Optional settings, added to the address after embed=1: &accent=0f6b5c (colour, 3 or 6 hex digits). Other parameters are ignored.

Please keep the credit link below the tool.

The Fire Department Shift Schedule provides an interactive calculation engine and calendar for rotating shift workers, team supervisors, and payroll managers. By analyzing scheduled shift hours, rest intervals, and overtime pay rules, this fire department shift schedule clarifies complex working patterns before duty begins. Whether planning crew coverage across a 28-day cycle or checking take-home compensation under federal and state wage statutes, the tool computes daily hours, weekly totals, and statutory overtime minute by minute. All roster calculations run entirely within your local browser, keeping your personal work history and wage inputs confidential. You can export completed rosters directly as an iCalendar (.ics) feed or download detailed spreadsheet data for administrative recordkeeping.

Open the calculator, enter your crew’s start date, and compare your 28-day hours with the 212-hour threshold.

At a glance

A fire department shift schedule is a three-platoon system of 24-hour tours. The three predominant schedules are the 24/48, the 48/96 and the Kelly schedule.

  • The three predominant schedules are the 24/48 (one day on, two days off), the 48/96 (two consecutive 24-hour days on, four days off), and the Kelly schedule.
  • In a standard 28-day work period, overtime triggers only after a firefighter works more than 212 hours.
  • Fire departments adopt work periods between 7 and 28 consecutive days under FLSA Section 7(k).
  • Because 24-hour platoons typically work between 216 and 240 hours in a 28-day cycle, firefighters accrue between 4 and 28 hours of statutory FLSA overtime pay each pay period at 1.5 times their regular rate of pay.
  • All roster calculations run entirely within your local browser, keeping your personal work history and wage inputs confidential.
Fire department shift schedule example

How to use the fire department shift schedule

  1. Select your roster configuration: Choose the active rotation pattern, team platoon, or shift schedule that matches your workplace employment agreement or collective bargaining contract.
  2. Set cycle starting anchors: Enter your crew's start date in the anchor field to synchronize the calendar cycle with your actual calendar dates across upcoming operating months.
  3. Define shift times and meal breaks: Confirm the start time, end time, and unpaid meal period minutes. Standard shift defaults are provided but can be tailored to exact site facility hours.
  4. Input regular wage rates: Enter your baseline hourly pay rate to generate gross earnings, night shift premium differentials, and statutory weekly overtime projections.
  5. Choose the applicable legal rule pack: Select standard federal FLSA guidelines, California daily overtime rules, or public safety FLSA Section 7(k) exemptions according to your specific industry jurisdiction.
  6. Mark schedule exceptions on the calendar: Tap individual calendar dates to log paid time off, sick leave, shift trades, or overtime pickups without breaking the underlying baseline rotation structure.
  7. Export and save roster files: Download your schedule as an iCalendar (.ics) file to sync with mobile devices or export a comprehensive CSV spreadsheet for payroll verification and records.

Your personal modifications, shift swaps, and hourly rate selections remain securely stored in this browser session, allowing you to return and review updated figures throughout the entire work year without re-entering data.

How do fire department shift schedules work?

Municipal fire departments universally utilize a three-platoon system (often designated Shift A, B, and C) to maintain uninterrupted round-the-clock emergency response. Firefighters work 24-hour tours of duty that combine active emergency response, apparatus maintenance, training, and station sleep time. The three predominant schedules are the 24/48 (one day on, two days off), the 48/96 (two consecutive 24-hour days on, four days off), and the Kelly schedule (alternating 24-hour shifts followed by an extended Kelly break).

Operational leaders and shift supervisors must continually balance continuous production goals with human physiological endurance. When teams maintain round-the-clock schedules, predictable shift sequences help operators plan family obligations, medical care, and personal commitments well in advance. Transparent scheduling reduces unscheduled absenteeism, turnover costs, and on-shift fatigue incidents across critical infrastructure operations.

Fire Service Shift Schedule Comparison (3-Platoon System)

Schedule NameTour StructureCycle LengthShifts per 28 DaysHours per 28 Days (24h)
24/48 Schedule1 on / 2 off3 days9 to 10 shifts216 to 240 hours
48/96 Schedule2 on / 4 off6 days9 to 10 shifts216 to 240 hours
Kelly Schedule1 on, 1 off, 1 on, 1 off, 1 on, 4 off9 days9 to 10 shifts216 to 240 hours
FLSA § 7(k) Statutory CapFire Protection 28-Day Threshold28 daysN/A212.0 maximum regular hours

FLSA Section 7(k) fire protection exemption rules

Under 29 U.S.C. § 207(k) and 29 CFR § 553.230, public fire protection agencies are exempt from the standard 40-hour weekly overtime threshold. Instead, fire departments adopt work periods between 7 and 28 consecutive days. In a standard 28-day work period, overtime triggers only after a firefighter works more than 212 hours. Because 24-hour platoons typically work between 216 and 240 hours in a 28-day cycle, firefighters accrue between 4 and 28 hours of statutory FLSA overtime pay each pay period at 1.5 times their regular rate of pay.

Understanding statutory shift thresholds prevents unexpected payroll discrepancies and ensures equitable rest distribution across all operational teams. When comparing rotations, always weigh the physiological benefits of extended recovery stretches against the cumulative fatigue incurred during intense multi-day work blocks. Proper roster design incorporates sufficient handover margins between shifts, transparent tracking of premium rate multipliers, and clear administrative procedures for voluntary overtime allocation.

How this tool works and where the numbers come from

The calculator maps rotation cycles day-by-day from your crew’s start date, tallying exact shift durations and meal breaks. Overtime is calculated across fixed workweeks or statutory 7(k) periods in accordance with federal FLSA regulations and state labor statutes. Results provide administrative estimates, not legal or payroll counsel.

Sources

Reviewed · Published by Shiftfigure

Frequently asked questions

What is the FLSA 7(k) exemption for firefighters?

FLSA Section 7(k) allows fire departments to establish work periods up to 28 days. In a 28-day period, overtime is owed only when hours exceed 212 (an average of 53 hours per week), rather than the traditional 40-hour private-sector threshold.

Why are many departments moving from 24/48 to 48/96?

The 48/96 schedule provides firefighters with four consecutive days off duty (96 hours) after every two-day tour, drastically reducing commuting expenses, improving home life, and providing longer consolidated recovery intervals compared to 48 hours off.

What is a Kelly day in a firefighter schedule?

A Kelly day is an extra scheduled day off inserted into a high-hour rotation to reduce a firefighter’s total hours worked in a pay period down to the contractually agreed baseline or to minimize FLSA overtime liabilities.

Can station sleep time be deducted from firefighter pay?

Under 29 CFR § 553.222, sleep time cannot be deducted from shifts of exactly 24 hours. For shifts exceeding 24 hours, up to 8 hours of sleep time may be excluded only if agreed in advance and if at least 5 hours of uninterrupted sleep can be obtained.

How do firefighters calculate Kelly days across the year?

A Kelly day is an extra scheduled day off inserted into a rotation to reduce scheduled hours down to agreed contract maximums, keeping total 28-day hours aligned with FLSA Section 7(k) standards.

How many hours do 24-hour platoons work in a 28-day cycle?

24-hour platoons typically work between 216 and 240 hours in a 28-day cycle, which is 9 to 10 shifts. Under FLSA Section 7(k), overtime in a 28-day work period starts after 212 hours. That means 4 to 28 hours of overtime per pay period, paid at 1.5 times the regular rate of pay.